{"id":14871,"date":"2019-08-18T14:19:13","date_gmt":"2019-08-18T14:19:13","guid":{"rendered":"https:\/\/www.mikroelektronika.net\/?page_id=14871"},"modified":"2021-10-12T14:40:41","modified_gmt":"2021-10-12T12:40:41","slug":"software-packages","status":"publish","type":"page","link":"https:\/\/www.mikroelektronika.net\/en\/software-packages\/","title":{"rendered":"Software packages \u03bcSys &#038; \u03bcMeter"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_empty_space height=&#8221;90px&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/6&#8243;][vc_column_text]<\/p>\n<h1>Software packages\u00a0\u03bcSys &amp; \u03bcMeter<\/h1>\n<p>[\/vc_column_text][vc_column_text]The software we offer is designed to easily allow the user to access a large amount of information that our meters collect about electricity consumption.<\/p>\n<p>Like our meters, the software contains all the information provided by the DLMS protocol, as well as IDIS.<\/p>\n<p>\u03bcMeter is a software tool for communication with a single meter and is intended for parameterization of meters for distribution, and can provide information about the supplied electricity and the user who has the need and desire to learn more about their consumption, in order to manage and make savings.<\/p>\n<p>\u03bcSys is a Head End solution, which is used to collect and process data from a larger group of meters, as well as to parameterize and manage that group of devices. This software can be used independently or to export the necessary data to other software, most often AMI or MDM systems that already in use\u00a0 by distributions.<\/p>\n<p>\u03bcSys can read all registers defined by the DLMS protocol and export them to the parent application in the required format, allowing distributions to manage our meters without having to make changes to their existing systems.[\/vc_column_text][vc_empty_space height=&#8221;20px&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;2\/6&#8243; css=&#8221;.vc_custom_1566133510334{padding-left: 30px !important;}&#8221;][vc_single_image image=&#8221;14647&#8243; img_size=&#8221;medium&#8221; css=&#8221;.vc_custom_1566137056761{padding-left: 30px !important;}&#8221;][\/vc_column_inner][\/vc_row_inner][vc_empty_space height=&#8221;30px&#8221;][\/vc_column][\/vc_row][vc_row full_width=&#8221;stretch_row_content_no_spaces&#8221;][vc_column][vc_row_inner equal_height=&#8221;yes&#8221;][vc_column_inner width=&#8221;1\/2&#8243; css=&#8221;.vc_custom_1566139661760{background-image: url(https:\/\/www.mikroelektronika.net\/wp-content\/uploads\/2019\/08\/microsys.jpg?id=14858) !important;background-position: center !important;background-repeat: no-repeat !important;background-size: cover !important;}&#8221;][vc_empty_space height=&#8221;300px&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243; css=&#8221;.vc_custom_1553647245203{padding-top: 20% !important;padding-right: 15% !important;padding-bottom: 20% !important;padding-left: 15% !important;background-color: #f2f2f2 !important;}&#8221;][vc_icon icon_fontawesome=&#8221;fa fa-check-circle&#8221; color=&#8221;green&#8221; size=&#8221;xl&#8221; align=&#8221;center&#8221;][vc_column_text]<\/p>\n<h5 style=\"text-align: center;\">The meters correspond to European standards EN 50470-1 and EN 50470-3, as well as to international standards IEC 62052-11 and IEC 62053-21, and are designed and manufactured according to ISO 9001 standard. The active and reactive electrical power meters, in addition to the specified standards, meet the requirements of international standard IEC62053-23.<\/h5>\n<p>[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_empty_space height=&#8221;70px&#8221;][\/vc_column][\/vc_row][vc_row disable_element=&#8221;yes&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_row_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;14816&#8243; img_size=&#8221;full&#8221; alignment=&#8221;right&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;.vc_custom_1566132724930{padding-right: 30px !important;}&#8221;]Active or active and reactive energy.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;14818&#8243; img_size=&#8221;full&#8221; alignment=&#8221;right&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;.vc_custom_1566132717595{padding-right: 30px !important;}&#8221;]Maximum power, integration period from 1 to 60 min.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;14820&#8243; img_size=&#8221;full&#8221; alignment=&#8221;right&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;.vc_custom_1566132733275{padding-right: 30px !important;}&#8221;]Measurement of energy in one or two directions or absolute measurement.<br \/>\n(+ A, + R; -A, -R; |A|, |R|), optionally by quadrants (R1, R2, R3, R4).[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;14822&#8243; img_size=&#8221;full&#8221; alignment=&#8221;right&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;.vc_custom_1566132743626{padding-right: 30px !important;}&#8221;]Internal multi-tariff registration or external management via tariff inputs\/ outputs.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;14824&#8243; img_size=&#8221;full&#8221; alignment=&#8221;right&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;.vc_custom_1566132763123{padding-right: 30px !important;}&#8221;]Internal real time counter with DST (Daylight saving enabled).<br \/>\nBack-up Li-Ion battery, optional super capacitor.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;14826&#8243; img_size=&#8221;full&#8221; alignment=&#8221;right&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;.vc_custom_1566132771238{padding-right: 30px !important;}&#8221;]Time profiles for measuring data (up to 6 channels).[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;14828&#8243; img_size=&#8221;full&#8221; alignment=&#8221;right&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;.vc_custom_1566132779084{padding-right: 30px !important;}&#8221;]Measurement of phase voltage and current and power factor.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;14830&#8243; img_size=&#8221;full&#8221; alignment=&#8221;right&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;.vc_custom_1566132793254{padding-right: 30px !important;}&#8221;]RS485 communication interface.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;14834&#8243; img_size=&#8221;full&#8221; alignment=&#8221;right&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;.vc_custom_1566132803451{padding-right: 30px !important;}&#8221;]For 3-phase 4- or 3-wire networks or single-phase 2-wire networks.[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;14836&#8243; img_size=&#8221;full&#8221; alignment=&#8221;right&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;2\/3&#8243;][vc_column_text css=&#8221;.vc_custom_1566132811202{padding-right: 30px !important;}&#8221;]Impulse output(s) (kWh or kWh + quark).[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text]\u2022 Simplicity, speed and ease of connecting the meter to the network,<br \/>\nindication of correct connection.<\/p>\n<p>\u2022 Self-extinguishing polycarbonate housing.<\/p>\n<p>\u2022 Compact design of meter according to DIN 43857.<\/p>\n<p>\u2022 IP54 degree of protection against penetration of moisture and dust.<\/p>\n<p>\u2022 High resistance to electromagnetic interference.<\/p>\n<p>\u2022 Monitoring and registering of violation of meter&#8217;s work integrity (opening of the upper or lower lid, strong magnetic field action, wrong password access attempt, &#8230;).<\/p>\n<p>\u2022 DLMS communication protocol.<\/p>\n<p>\u2022 Possibility of switching into a remote measurement and management system by installing one of the communication modules-GSM\/GPRS, PLC (S-FSK, DCSK, G3), ETHERNET, Zigbee.<\/p>\n<p>\u2022 Indication of the working condition of the meter and the communication module.<\/p>\n<p>\u2022 Relay outputs for remote and local load control.<\/p>\n<p>\u2022 Power monitoring and load control with integrated or external switch to a maximum current of 100 A.<\/p>\n<p>\u2022 Optical output(s):<br \/>\n&#8211; direct connection &#8211; 1000 imp\/kWh (kvarh)<br \/>\n&#8211; semi-indirect connection &#8211; 10 000 imp\/kWh (kvarh)<br \/>\n&#8211; indirect connection &#8211; 40 000 imp\/kWh (kvarh)<\/p>\n<p>\u2022 LIST and SET buttons (the ability to seal the SET key).[\/vc_column_text][\/vc_column][\/vc_row][vc_row disable_element=&#8221;yes&#8221;][vc_column][vc_empty_space][\/vc_column][\/vc_row][vc_row full_width=&#8221;stretch_row&#8221; disable_element=&#8221;yes&#8221; css=&#8221;.vc_custom_1566158796123{margin-top: 0px !important;margin-bottom: 0px !important;background-color: #f2f2f2 !important;}&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;14846&#8243; img_size=&#8221;full&#8221; alignment=&#8221;right&#8221; css=&#8221;.vc_custom_1566134248977{padding-right: 30px !important;padding-left: 80px !important;}&#8221;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text css=&#8221;.vc_custom_1566134736318{padding-top: 20px !important;}&#8221;]\u2022 LCD display with backlight.<\/p>\n<p>\u2022 Tagging data by OBIS code: IEC 62056-61.<\/p>\n<p>\u2022 A programmable data set and display sequence, manually and automatically.[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_empty_space height=&#8221;90px&#8221;][vc_row_inner][vc_column_inner width=&#8221;4\/6&#8243;][vc_column_text] Software packages\u00a0\u03bcSys &amp; \u03bcMeter [\/vc_column_text][vc_column_text]The software we offer is designed to easily allow the user to access a large amount of information that our meters collect about [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"no-footer.php","meta":[],"_links":{"self":[{"href":"https:\/\/www.mikroelektronika.net\/en\/wp-json\/wp\/v2\/pages\/14871"}],"collection":[{"href":"https:\/\/www.mikroelektronika.net\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mikroelektronika.net\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mikroelektronika.net\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mikroelektronika.net\/en\/wp-json\/wp\/v2\/comments?post=14871"}],"version-history":[{"count":6,"href":"https:\/\/www.mikroelektronika.net\/en\/wp-json\/wp\/v2\/pages\/14871\/revisions"}],"predecessor-version":[{"id":15393,"href":"https:\/\/www.mikroelektronika.net\/en\/wp-json\/wp\/v2\/pages\/14871\/revisions\/15393"}],"wp:attachment":[{"href":"https:\/\/www.mikroelektronika.net\/en\/wp-json\/wp\/v2\/media?parent=14871"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}